GARO offers two programs of the miniature components, 10kA & 6kA. Both programs consist of miniature circuit breakers (mcb), residual current detectors (rcd), and residual current detectors with integral over-current protection (rcbo). There is a full program of 10kA components, which fit most applications, and a limited program of the 6kA range.The two switches are not compatible with each other... The 6kA program consists of components of excellent quality, with limited additional features. The range comes in 1,2,3 & 4 Pole versionsTested by Intertek SEMKO according to standards EN 60898-1 and EN 60947-2.B-Characteristic 3 - 5 x In:-Resistive loadsLights and socketsCookers and ovensWater heatersRadiatorsTECHNICAL DATA BREAKER 6kA:-Energy Restriction Class..... 3Connection Area.............. 1-25 mm²Max Torque................... 3,5 NmProtection Class............. IP20Rated Voltgage............... 230/400V ACAmbient Temperature.......... –25..+40 ºC
GARO offers two programs of the miniature components, 10kA & 6kA. Both programs consist of miniature circuit breakers (mcb), residual current detectors (rcd), and residual current detectors with integral over-current protection (rcbo). There is a full program of 10kA components, which fit most applications, and a limited program of the 6kA range.The two switches are not compatible with each other. The 6kA program consists of components of excellent quality, with limited additional features. The range comes in 1,2,3 & 4 Pole versionsTested by Intertek SEMKO according to standards EN 60898-1 and EN 60947-2.C-Characteristic 5 - 10 x In:-Inductive and resistive loadsMicrowavesMotorsOutletsWashers and DryersTECHNICAL DATA BREAKER 6kA:-Energy Restriction Class..... 3Connection Area.............. 1-25 mm²Max Torque................... 3,5 NmProtection Class............. IP20Rated Voltgage............... 230/400V ACAmbient Temperature.......... –25..+40 ºC
The RCBO is a combination of an RCCB and MCB. Both the 10kA and 6kA ranges are Type A and can be supplied from the top or bottom. The products are approved and certified according to EN 61009. GARO RCBOs 10kA & 6kA Type…………………………………..ARated Voltage…………………….230V ACMax Torque………………………..3NmProtection Class………………….IP20
1Mod Residual Current Breaker with Overcurrent ProtectionRated voltage Un................230Vac.Rated current In................6-25AMinimal supply voltage Umin.....90VRated frequency fn..............50HzRated short-circuit capacity....6kATripping characteristic.........B or C Rated residual current l?n......10,30,100mAType of residual release........ATerminals.......................1-10mm2Width...........................18mmStandard........................IEC 61009
GARO's. range of RCCBs in 10kA are Type A, and are tested and certified to standard EN 61008.The range can be fed from the TOP or BOTTOM.GARO's 10kA RCCB range is designed for use in industrial and domestic applications and is rated for short-circuit currents up to 10kA. GARO RCCBs Type A Rated Voltgage 230/400V AC Max Torque 3 Nm Protection Class IP20
Auxiliary contacts for use with GARO’s range of 6kA and 10kA breakers.Used for remote indication of the status of the respective breaker. Each auxiliary contact is 0.5modules width, 1NO & 1NC contact
GARO offers two programs of the miniature components, 10kA & 6kA. Both programs consist of miniature circuit breakers (mcb), residual current detectors (rcd), and residual current detectors with integral over-current protection (rcbo). There is a full program of 10kA components, which fit most applications, and a limited program of the 6kA range.The two switches are not compatible with each other. The 10kA range is a professional program for the industrial segment and more demanding installations.These MCBs are suitable for all applications and are equipped with a mounting bracket that makes it possible to remove or install an MCB even when busbar is fitted.The components are available with B,C and D characteristics, in 1,1+n,2,3,& 4 pole.Tested by Intertek SEMKO according to standards EN 60898-1 and EN 60947-2.B-Characteristic 3 - 5 x In:-Resistive loadsLights and socketsCookers and ovensWater heatersRadiatorsTECHNICAL DATA BREAKER 10kA:-Energy Restriction Class..... 3Connection Area.............. 1-25 mm²Max Torque................... 3,5 NmProtection Class............. IP20Rated Voltgage............... 230/400V AC, max 60VDC, min 12VDCAmbient Temperature.......... –25..+55ºC
GARO offers two programs of the miniature components, 10kA & 6kA. Both programs consist of miniature circuit breakers (mcb), residual current detectors (rcd), and residual current detectors with integral over-current protection (rcbo). There is a full program of 10kA components, which fit most applications, and a limited program of the 6kA range.The two switches are not compatible with each other. The 10kA range is a professional program for the industrial segment and more demanding installations.These MCBs are suitable for all applications and are equipped with a mounting bracket that makes it possible to remove or install an MCB even when busbar is fitted.The components are available with B,C and D characteristics, in 1,1+n,2,3,& 4 pole.Tested by Intertek SEMKO according to standards EN 60898-1 and EN 60947-2.C-Characteristic 5 - 10 x In:-Inductive and resistive loadsMicrowavesMotorsOutletsWashers and DryersTECHNICAL DATA BREAKER 10kA:-Energy Restriction Class..... 3Connection Area.............. 1-25 mm²Max Torque................... 3,5 NmProtection Class............. IP20Rated Voltgage............... 230/400V AC, max 60VDC, min 12VDCAmbient Temperature.......... –25..+55ºC
GARO offers two programs of the miniature components, 10kA & 6kA. Both programs consist of miniature circuit breakers (mcb), residual current detectors (rcd), and residual current detectors with integral over-current protection (rcbo). There is a full program of 10kA components, which fit most applications, and a limited program of the 6kA range.The two switches are not compatible with each other. The 10kA range is a professional program for the industrial segment and more demanding installations.These MCBs are suitable for all applications and are equipped with a mounting bracket that makes it possible to remove or install an MCB even when busbar is fitted.The components are available with B,C and D characteristics, in 1,1+n,2,3,& 4 pole.Tested by Intertek SEMKO according to standards EN 60898-1 and EN 60947-2.D-Characteristic 10 - 20 x In:-Start power loadsWelding activityLiftsTruck chargersTECHNICAL DATA BREAKER 10kA:-Energy Restriction Class..... 3Connection Area.............. 1-25 mm²Max Torque................... 3,5 NmProtection Class............. IP20Rated Voltgage............... 230/400V AC, max 60VDC, min 12VDCAmbient Temperature.......... –25..+55ºC
Function: SIRCO VM1 changeover switches are manually operated three or four pole changeover switches. They provide changeover, source inversion or switching under load between two low voltage power circuits, as well as their safety isolation.General characteristics• Safety isolation by fully visible double breaking. • DIN rail mounting, panel or modular panel with 45 mm front cut out. • IP20 devices and accessories.Conformity to standards:IEC 60947-3IS 14947-3EN 60947-3VDE 0660-107 (1992) NBN EN 60947-3BS EN 60947-3
HAND-OFF-AUTO toggle & dolly type changeover switchesAC22 certified to EN60947.Enclosure class IP20
CTU & DCTU:Emergency Light Test relays for din and surface mounting.2235A &3875A:Electronic Time Lag switches with push button or touch pad rated at 16A.COLUMBUS:Time Delay Switch at 6A timed from 5 seconds to 20 minutes. STAIRCASE TIMERS:For the control of range lighting e.g. stairwells. Switchable for 3 functions with different time intervals as well as ignition and extinguishing functions.DIGITAL TIMERS: Digital and Astronomical time switches with daily and weekly adjustable programs.Battery reserve of 3 years (Li-ion type CR-2032). Charge reserve of 1 minute (for battery replacement).Halogen and incandescent = 1500W (a 240V). Fluorescent = 600W (a 240V)CHRONOTHERMOSTATS: Weekly programming has 3 values of temperature regulation, adjustable for each hour during the day
• Installation contactors are used in distribution boards in dwellings, business premises, hotels, hospitals, shopping centres, sport & leisure centres, production halls, warehouses and public places• They are used for remote switching and automatic control of electric devices and equipment, such as:- single-phase and three-phase motors- different pumps- air-conditioning- electric heating- lighting• Basic contactor types are: GK20, GK24, GK40, and GK63• GK24, GK40 and GK63 with a varistor for overvoltage protection and a rectifier enable dc and ac voltage control• They excel in silent operation• GK20 is an ac driven contactor only• Contacts can be used as main or auxiliary• Contactors are designed for assembling to 35mm mounting rail in accordance with the EN60715 standard• Sealing terminal covers enable direct protection against contact with live parts• IKV ventilation module is available for preventing exceeded heating when contactors are used side-by-side• All contactors have degree of protection IP20
Standard kWh meters in single and three phase models for the measurement of energy consumption, according to EN50470
Apparatus for use in distribution boards, with a width of 17.5 mm, suitable for cable connectivity between 1.5-6 mm ².Indicator lights are up to 1.5 W / 230V with E10 socket.The equipment is verified and validated to standard EN 60 947-3, EN 60 947-5-1 and DIN 43880 and DIN VDE 0710.
Standard apparatus typically suited to GARO's domestic consumer units.Enclosure class IP20.
A simple Guide to Surge ProtectionA surge protective device (SPD) which is connected at the main distribution board is constantly monitoring the supply voltage. When a voltage surge that exceeds the rating of the SPD is detected, the SPD conducts the surge directly to earth, away from the installation. This protects the equipment and products that have been connected.All products incorporating electronics e.g. TV, computer, washing machine, fridge, light fittings, phone chargers, etc. are at risk of damage, complete loss, and even fire, if surge protective devices are not fitted. This can cause huge expense that may not be covered by insurance. Surge protective devices are an extremely inexpensive method of protecting any installation.Here are some simple guidelines to the use of surge protective devices: • CLASS 1 surge protective device should be installed at the main distribution board: - where there is an external LIGHTNING PROTECTION SYSTEM installed on a building (lightning conductors, earth rods etc.). • CLASS 11 surge protective device should be installed at the main distribution board:- where there is not a lightning protection system fitted. • CLASS 111 surge protective device should additionally be installed, locally, for more sensitive equipment. The only installations not requiring surge protection devices are those that do not incorporate any electronics.GARO has launched a comprehensive range of Surge Protective Device’s (SPD) to meet the requirements of all modern electrical installations.
STV Type SWITCH-DISCONNECTOR-FUSEA device which combines the functions of the switch and of the fuse D0.The system enables the following advantages of protection in comparison with the fuse D0:- The changing of the fuse-link without danger of direct touch of parts under voltage. - Snap-on mounting on rail according to EN 60715. - The complete protection against touch according to VBG 4. - The possibility of connecting supply from the upper or from the lower side. - It can be used as a main switch and tariff fuse in a single device. - Possibility of sealing in ON or OFF positions with or without fuse-link. The GARO TYTAN II fuse disconnect switchDesigned with safety in mind. This “CARTRIDGE “ style unit has some unique safety features:• It allows visible inspection of the fuse connections before switching on. • Various cartridge sizes are available to suit fuses ranging from 6A - 63A.• Corresponding gauges ensure that only the appropriate size cartridge and fuse can be used.• The cartridge design ensures that the fuse contact pressures remain constant throughout use.Certified to IEC 60695-2-1
A range of accessories for use with GARO components